When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Load balancing (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Load_balancing_(electrical...

    Electrical substation. Load balancing, load matching, or daily peak demand reserve refers to the use of various techniques by electrical power stations to store excess electrical power during low demand periods for release as demand rises. [1] The aim is for the power supply system to have a load factor of 1.

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    An unbalanced system is analysed as the superposition of three balanced systems, each with the positive, negative or zero sequence of balanced voltages. When specifying wiring sizes in a three-phase system, we only need to know the magnitude of the phase and neutral currents.

  4. Balanced circuit - Wikipedia

    en.wikipedia.org/wiki/Balanced_circuit

    A circuit that has the specific purpose of allowing interfacing between balanced and unbalanced circuits is called a balun. A balun could be a transformer with one leg earthed on the unbalanced side as described in the transformer balance section above. Other circuits are possible such as autotransformers or active circuits. [4]

  5. Balun - Wikipedia

    en.wikipedia.org/wiki/Balun

    A balun / ˈ b æ l ʌ n / (from "balanced to unbalanced", originally, but now derived from "balancing unit") [1] is an electrical device that allows balanced and unbalanced lines to be interfaced without disturbing the impedance arrangement of either line. [2] A balun can take many forms and may include devices that also transform impedances ...

  6. Balanced line - Wikipedia

    en.wikipedia.org/wiki/Balanced_line

    A signal transmitted over a balanced line. The signal is kept intact while the noise (which appears as a common-mode signal at the receiving end) is rejected perfectly.. In telecommunications and professional audio, a balanced line or balanced signal pair is an electrical circuit consisting of two conductors of the same type, both of which have equal impedances along their lengths, to ground ...

  7. Unbalanced circuit - Wikipedia

    en.wikipedia.org/wiki/Unbalanced_circuit

    However, connecting an unbalanced circuit to, for instance, a twisted pair line, which is an intrinsically balanced format, makes the line susceptible to common-mode interference. [citation needed] For this reason, balanced lines are normally driven from balanced circuits. One option is to redesign the circuit so that it is properly impedance ...

  8. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Two-phase motors draw constant power, just as three-phase motors do, so a balanced two-phase load is converted to a balanced three-phase load. However if a two-phase load is not balanced (more power drawn from one phase than the other), no arrangement of transformers (including the Scott-T transformers) can restore balance: Unbalanced current ...

  9. Load management - Wikipedia

    en.wikipedia.org/wiki/Load_management

    Since electrical energy is a form of energy that cannot be effectively stored in bulk, it must be generated, distributed, and consumed immediately. When the load on a system approaches the maximum generating capacity, network operators must either find additional supplies of energy or find ways to curtail the load, hence load management.