Search results
Results From The WOW.Com Content Network
If the boiler is of the high efficiency condensing type, high turndown ratios are feasible and the higher the turndown ratio, the more efficient it will be. Every time a gas/oil boiler stops, it has to be "purged" with cold air to remove any combustible gases that may have accumulated in the boiler before restarting.
Boilers have a turndown ratio which is the ratio of the maximum power output to the minimum power output for which combustion can be maintained. If the control system determines that the demand falls below the minimum power output, then the boiler will cycle off until the water temperature has fallen, and then will reignite and heat the water.
Turndown ratio; V. Volumetric efficiency; W. Water–cement ratio This page was last edited on 6 April 2016, at 23:36 (UTC). Text is available under the Creative ...
erosion of a boiler's plates from the internal water space, particularly where there is a step inside the shell. This was a problem for early boilers made from lapped plates rather than butted plates, and gave rise to many boiler explosions. In later years it was a problem for the non-circular water drums of Yarrow boilers. Handhole
A boiler is a closed vessel in which fluid (generally water) is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, [1] [page needed] [2] [page needed] including water heating, central heating, boiler-based power generation, cooking, and sanitation.
The annual fuel utilization efficiency (AFUE; pronounced 'A'-'Few' or 'A'-'F'-'U'-'E') is a thermal efficiency measure of space-heating furnaces and boilers.The AFUE differs from the true 'thermal efficiency' in that it is not a steady-state, peak measure of conversion efficiency, but instead attempts to represent the actual, season-long, average efficiency of that piece of equipment ...
This committee put in the form work for the first edition of the ASME Boiler Code - Rules for the Construction of Stationary Boilers and for the Allowable Working Pressures, which was issued in 1914 and published in 1915. [5] The first edition of the Boiler and Pressure Vessel Code, known as the 1914 edition, was a single 114-page volume.
This results in a definition for specific mass capacity as follows: = Here, represents the mass ratio of gas 'x' (meaning mass of gas 'x' relative to the mass of all other non-'x' gas mass) and is the partial pressure of gas 'x'. Using the ideal gas formulation for the mass ratio gives the following definition for the specific mass capacity: