When.com Web Search

  1. Ads

    related to: basic pressure relief valves

Search results

  1. Results From The WOW.Com Content Network
  2. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  3. List of valves - Wikipedia

    en.wikipedia.org/wiki/List_of_valves

    The sheet has a solid end and a flow-through end; sliding it from one position to the other opens or stops the flow. Also called sliding blind valve; Outflow valve: regulates flow and pressure, part of cabin pressurization; Pilot valve: regulates flow or pressure to other valves; Petcock, a small shut-off valve

  4. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    At set pressure the valve snaps to full lift. This can be quite violent on large pipes with significant pressure. The pressure has to drop below the set pressure in order for the piston to reseat (see blowdown in relief valve article). Modulating The pilot is designed to open gradually, so that less of the system fluid is lost during each ...

  5. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  6. High-integrity pressure protection system - Wikipedia

    en.wikipedia.org/wiki/High-integrity_pressure...

    In traditional systems over-pressure is dealt with through relief systems. A relief system will open an alternative outlet for the fluids in the system once a set pressure is exceeded, to avoid further build-up of pressure in the protected system. This alternative outlet generally leads to a flare or venting system to safely dispose the excess ...

  7. Pneumatic circuit - Wikipedia

    en.wikipedia.org/wiki/Pneumatic_circuit

    The normally closed valves will not permit flow from the inlet port of the valve to the outlet port, normally the flow will be permitted only by changing the position of the valve. In general, valves are designated as 2/2 DCV, 3/2 DCV, 5/2 DCV, 5/3 DCV etc., in which the first number indicates number of ports and second number indicates number ...