Ads
related to: phased array transducer
Search results
Results From The WOW.Com Content Network
By changing the pulse delays, the computer can scan the beam of ultrasound in a raster pattern across the tissue. Echoes reflected by different density tissue, received by the transducers, build up an image of the underlying structures. Weld examination by phased array. TOP: The phased array probe emits a series of beams to flood the weld with ...
A phased array of acoustic transducers, denominated airborne ultrasound tactile display (AUTD), was developed in 2008 at the University of Tokyo's Shinoda Lab to induce tactile feedback. [37] This system was demonstrated to enable a user to interactively manipulate virtual holographic objects. [38]
A typical radiation pattern of phased arrays whose inter-element spacing is greater than half a wavelength, hence the radiation pattern has grating lobes.. For discrete aperture antennas (such as phased arrays) in which the element spacing is greater than a half wavelength, a spatial aliasing effect allows plane waves incident to the array from visible angles other than the desired direction ...
At a construction site, a technician tests a pipeline weld for defects using an ultrasonic phased array instrument. The scanner, which consists of a frame with magnetic wheels, holds the probe in contact with the pipe by a spring. The wet area is the ultrasonic couplant that allows the sound to pass into the pipe wall.
Phased Array Ultrasonic Transducers are a collection of ultrasonic speakers which are controlled to create a single desired sound field. This is achieved by controlling the relative phase (i.e. the delay time) between each output, and sometimes the relative output magnitudes.
An optical phased array (OPA) is the optical analog of a radio-wave phased array. [1] By dynamically controlling the optical properties of a surface on a microscopic scale, it is possible to steer the direction of light beams (in an OPA transmitter [ 2 ] ), or the view direction of sensors (in an OPA receiver [ 3 ] ), without any moving parts.
TOFD has a dead zone where it is not sensitive to defects, hence TOFD ought always to be supplemented by a conventional pulse-echo examination or phased array. The pulse echo probes are commonly mounted on the same buggy as the TOFD probes. Requires ultrasound technicians with advanced training.
A transducer may be swept mechanically by rotating or swinging or a 1-D phased array transducer may be used to sweep the beam electronically. The received data is processed and used to construct the image. The image is then a 2-D representation of the slice into the body.