Search results
Results From The WOW.Com Content Network
The windings of the transformer have inductance. Capacitors placed across the transformer windings form resonant circuits which provide the tuning of the amplifier. A further detail that may be seen in this kind of amplifier is the presence of taps on the transformer windings. These are used for the input and output connections of the ...
Fig. 1 L P σ and L S σ are primary and secondary leakage inductances expressed in terms of inductive coupling coefficient under open-circuited conditions.. The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ.
On the inside, the configuration of the wire windings makes it different. The stator portion of the resolver houses three windings: an exciter winding and two two-phase windings (usually labeled "x" and "y") (case of a brushless resolver). The exciter winding is located on the top; it is a coil of a turning (rotary) transformer.
Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases on the three-phase side.
For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.
For voltage ratios that don't exceed about 3:1, an autotransformer is cheaper, lighter, smaller, and more efficient than an isolating (two-winding) transformer of the same rating. [3] Large three-phase autotransformers are used in electric power distribution systems, for example, to interconnect 220 kV and 33 kV sub-transmission networks or ...
The flyback converter can be viewed as two inductors sharing a common core with opposite polarity windings. In contrast, the forward converter (which is based on a transformer with same-polarity windings, higher magnetizing inductance, and no air gap) does not store energy during the conduction time of the switching element — transformers ...
The low voltage side of the instrument transformer, with dot and X1 marking. The X1 and H1 terminals are adjacent. In electrical engineering, dot marking convention, or alphanumeric marking convention, or both, can be used to denote the same relative instantaneous polarity of two mutually inductive components such as between transformer ...