When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Fig. 1 L P σ and L S σ are primary and secondary leakage inductances expressed in terms of inductive coupling coefficient under open-circuited conditions.. The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ.

  3. Resolver (electrical) - Wikipedia

    en.wikipedia.org/wiki/Resolver_(electrical)

    On the inside, the configuration of the wire windings makes it different. The stator portion of the resolver houses three windings: an exciter winding and two two-phase windings (usually labeled "x" and "y") (case of a brushless resolver). The exciter winding is located on the top; it is a coil of a turning (rotary) transformer.

  4. Bifilar coil - Wikipedia

    en.wikipedia.org/wiki/Bifilar_coil

    Non-inductive bifilar winding Nikola Tesla's flat inductive bifilar coil. A bifilar coil is an electromagnetic coil that contains two closely spaced, parallel windings. In electrical engineering, the word bifilar describes wire which is made of two filaments or strands. It is commonly used to denote special types of winding wire for ...

  5. Coil winding technology - Wikipedia

    en.wikipedia.org/wiki/Coil_winding_technology

    An orthocyclic winding design for a round coil with 150 windings, a wire diameter of 0.3 mm and a maximum winding width of 9 mm shall be calculated. The winding diameter at the winding base measures 8 mm. Structure of a coil with an even number of turns per. Given: Wire-Ø Cu 0,3 mm → CU1L=0,334 mm (According to the table)

  6. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases on the three-phase side.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    For voltage ratios that don't exceed about 3:1, an autotransformer is cheaper, lighter, smaller, and more efficient than an isolating (two-winding) transformer of the same rating. [3] Large three-phase autotransformers are used in electric power distribution systems, for example, to interconnect 220 kV and 33 kV sub-transmission networks or ...

  8. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.

  9. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.