Figure 1: Schematic layout of a White-light Interferometer. A CCD image sensor like those used for digital photography is placed at the point where the two images are superimposed. A broadband “white light” source is used to illuminate the test and reference surfaces. A condenser lens collimates the light from the broadband light source.
Figure 3. White light interferometric microscope. White-light interferometry scanning (WLS) systems capture intensity data at a series of positions along the vertical axis, determining where the surface is located by using the shape of the white-light interferogram, the localized phase of the interferogram, or a combination of both shape and phase.
Michelson interferometers using a white light source White light has a tiny coherence length and is difficult to use in a Michelson (or Mach–Zehnder ) interferometer. Even a narrowband (or "quasi-monochromatic") spectral source requires careful attention to issues of chromatic dispersion when used to illuminate an interferometer.
Watson interferometer (microscopy) White-light interferometer (see also Optical coherence tomography, White light interferometry, and Coherence Scanning Interferometry) White-light scatterplate interferometer (white-light) (microscopy) Young's double-slit interferometer; Zernike phase-contrast microscopy
Figure 1. The light path through a Michelson interferometer.The two light rays with a common source combine at the half-silvered mirror to reach the detector. They may either interfere constructively (strengthening in intensity) if their light waves arrive in phase, or interfere destructively (weakening in intensity) if they arrive out of phase, depending on the exact distances between the ...
White light interferometers [9] Confocal Microscopes [7] Fringe projection profilometers [30] Management of missing/bad data points Field expansion by stitching 3D true-color management (topography+color) MountainsSEM Scanning electron microscopes: 3D reconstruction from a stereo pair [31] 3D reconstruction using a 4-quadrant detector
Optical coherence tomogram of a fingertip. It is possible to observe the sweat glands, having "corkscrew appearance" Interferometric reflectometry of biological tissue, especially of the human eye using short-coherence-length light (also referred to as partially-coherent, low-coherence, or broadband, broad-spectrum, or white light) was investigated in parallel by multiple groups worldwide ...
English: Michelson interferometer using white light. White light has only a very limited coherence length. When using a white light source, the two optical paths must be equal for all wavelengths. To meet this requirement, both the longitudinal and transverse light paths must cross an equal thickness of glass of the same dispersion.