Ads
related to: 1500 watts to btu hr system diagram layout chart- Human Resource Management
All-In-One HRM Software.
Ensure Your HRM Moves Smoothly.
- Pricing & Plans
Get Pricing for BambooHR Now.
Flexible Plan Options & Add-Ons.
- Performance Management
Make Performance Evaluation Simple
& Meaningful with BambooHR.
- Employee Time Tracking
Simplify Employee Time Off,
Scheduling, Attendance & More.
- Payroll Software
Combine Your HR Systems Into One -
HR, Payroll, Benefits & More.
- Onboarding Software
Manage Employee Onboarding & Create
Better First Days for New Hires.
- Human Resource Management
hibob.com has been visited by 10K+ users in the past month
Search results
Results From The WOW.Com Content Network
HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU/watt-hr. The higher the HSPF rating of a unit, the more energy efficient it is. An electrical resistance heater, which is not considered efficient, has an HSPF of 3.41. [3]
The SI unit of power for heating and cooling systems is the watt. Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20]
The cooling load temperature difference (CLTD) calculation method, also called the cooling load factor (CLF) or solar cooling load factor (SCL) method, is a method of estimating the cooling load or heating load of a building.
One BTU is the energy required to raise one pound of water one degree Fahrenheit, but the many different types of BTU are based on different interpretations of this “definition”. In the United States the power of HVAC systems (the rate of cooling and dehumidifying or heating) is sometimes expressed in BTU/hour instead of watts.
For example, consider a 5000 BTU/h (1465-watt cooling capacity) air-conditioning unit, with a SEER of 10 BTU/(W·h), operating for a total of 1000 hours during an annual cooling season (e.g., 8 hours per day for 125 days). The annual total cooling output would be: 5000 BTU/h × 8 h/day × 125 days/year = 5,000,000 BTU/year
Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)
units: approximately 1000 BTU/hour 3 × 10 2: tech: PC GPU Nvidia GeForce RTX 4080 peak power consumption [20] 4 × 10 2: tech: legal limit of power output of an amateur radio station in the United Kingdom 5 × 10 2: biomed: power output (useful work plus heat) of a person working hard physically 7.457 × 10 2: units: 1 horsepower [21] 7.5 × 10 2
This equivalent ton is defined as the heat rejection in cooling 3 US gallons per minute (11 litres per minute) or 1,500 pounds per hour (680 kg/h) of water by 10 °F (5.6 °C), which amounts to 15,000 British thermal units per hour (4.4 kW), assuming a chiller coefficient of performance (COP) of 4.0. [14]
Ads
related to: 1500 watts to btu hr system diagram layout chart