  2. Fanno flow - Wikipedia

    en.wikipedia.org/wiki/Fanno_flow

    For a flow with an upstream Mach number greater than 1.0 in a sufficiently long duct, deceleration occurs and the flow can become choked. On the other hand, for a flow with an upstream Mach number less than 1.0, acceleration occurs and the flow can become choked in a sufficiently long duct. It can be shown that for flow of calorically perfect ...

  3. File:Equal-friction chart for air in metal duct (ε = 0.05mm ...

    en.wikipedia.org/wiki/File:Equal-friction_chart...

    English: A graphical depiction of the relationship between S = Δ p / L, the pressure loss per unit length of pipe, versus flow volume Q, for a range of choices for pipe diameter D, for air at standard temperature and pressure. Units are SI. Lines of constant flow velocity V and lines of constant

  4. NACA duct - Wikipedia

    en.wikipedia.org/wiki/NACA_duct

    When properly implemented, a NACA duct allows air to flow into an internal duct, often for cooling purposes, with a minimal disturbance to the flow. The design was originally called a submerged inlet, since it consists of a shallow ramp with curved walls recessed into the exposed surface of a streamlined body, such as an aircraft .

  5. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  6. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Downstream of the air handler, the supply air trunk duct will commonly fork, providing air to many individual air outlets such as diffusers, grilles, and registers. When the system is designed with a main duct branching into many subsidiary branch ducts, fittings called take-offs allow a small portion of the flow in the main duct to be diverted ...

  7. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  8. Atkinson resistance - Wikipedia

    en.wikipedia.org/wiki/Atkinson_resistance

    is the air density in the duct (pounds per cubic foot), is the standard air density (0.075 pound per cubic foot), is the resistance (atkinsons), is the rate of flow of air (thousands of cubic feet per second).

  9. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.