Ads
related to: ashrae 110 testing procedure
Search results
Results From The WOW.Com Content Network
[9]: 50–52, 59 Standardized testing and certification procedures such as ANSI Z9.5 and ASHRAE 110 can be used, as can qualitative indicators of proper installation and functionality such as inspection of gaskets and hoses. [9]: 59–60 [13]: 14–15
Air filtration standards differ between the U.S. and other countries. The American ASHRAE rating system does not account for changes in filtration efficiency due to electrostatic charge. These MERV ratings do not account for a decrease in efficiency over the first few weeks of use due to a drop in static charge.
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.
Minimum Efficiency Reporting Value, commonly known as MERV, is a measurement scale designed in 1987 by the American Society of Heating, Refrigerating and Air-Conditioning Engineers to report the effectiveness of air filters in more detail than other ratings.
The now commonly used procedure, introduced by Eklöf and Gehlin in 1996 and now approved by ASHRAE involves inserting a pipe loop deep into the ground (in a well bore, filling the anulus of the bore with a grout substance of known thermal properties, heating the fluid in the pipe loop, and measuring the temperature drop in the loop from the ...
The AHAM-certified seal lists a rating for tobacco smoke, pollen, and dust removal, and a rating for room size. The clean air delivery rate (CADR) is a figure of merit that is the cubic feet per minute (CFM) of air that has had all the particles of a given size distribution removed.