The EPA defines refrigerant reclamation as "Reclaim refrigerant means to reprocess refrigerant to at least the purity specified in appendix A to 40 CFR part 82, subpart F (based on AHRI Standard 700–1993, Specifications for Fluorocarbon and Other Refrigerants) and to verify this purity using the analytical methodology prescribed in appendix A ...
For Type I systems the main requirement is to remove 80% of the refrigerant if the appliance's compressor is not running and 90% if running and evacuate to a 4 inch Hg vacuum. For Type II or Type III applications, the appliance must be evacuated to the following levels for device manufactured after November 15, 1993 in order to recover the ...
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.
ASHRAE's Handbook Committee maintains an Authors and Revisers Guide, which can be obtained freely via the Handbook portion of the ASHRAE Web site. While each new or revised chapter manuscript is to be reviewed for technical content by each TC voting and corresponding member before publication, there are often many other pre- and post ...
The International Institute of Refrigeration (IIR) (also known, in French, as the Institut International du Froid (IIF)), is an independent intergovernmental science and technology-based organization that promotes knowledge of refrigeration and associated technologies and applications on a global scale that improve quality of life in a cost-effective and environmentally sustainable manner ...
This is an auto-cascade process with two different refrigerants. The high-temperature refrigerant (red) condenses in the air condenser and is then separated and evaporated to cool the heat exchanger, which condenses the low-temperature refrigerant (blue). Purple signifies a mixture of both refrigerants.
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
R-410A is a refrigerant fluid used in air conditioning and heat pump applications. It is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125). R-410A is sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A.