  2. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    The focus of the first lens is traditionally about 2mm away from the plane face coinciding with the sample plane. A pinhole cap can be used to align the optical axis of the condenser with that of the microscope. The Abbe condenser is still the basis for most modern light microscope condenser designs, even though its optical performance is poor.

  3. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    A bright-field microscope has many important parts including; the condenser, the objective lens, the ocular lens, the diaphragm, and the aperture. Some other pieces of the microscope that are commonly known are the arm, the head, the illuminator, the base, the stage, the adjusters, and the brightness adjuster.

  4. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    In order to test the alignment of components on the light source image plane, the eyepiece must be removed to allow observation of the intermediate image plane (the position of the eyepiece diaphragm) either directly or by using a phase telescope/Bertrand lens. The light source (e.g. the bulb filament) and the edges of the condenser diaphragm ...

  5. Diaphragm (optics) - Wikipedia

    en.wikipedia.org/wiki/Diaphragm_(optics)

    Nine-blade iris Pentacon 2.8/135 lens with 15-blade iris Aperture mechanism of Canon 50mm f/1.8 II lens, with five blades In the human eye, the iris (light brown) acts as the diaphragm and continuously constricts and dilates its aperture (the pupil) A 750nm titanium-sapphire laser beam passing through an iris diaphragm, while opening and closing the iris.

  6. Dispersion staining - Wikipedia

    en.wikipedia.org/wiki/Dispersion_staining

    A requirement for this method is that the incoming beam of light is as parallel as possible. This requires the closing down of the sub-stage condenser iris. Closing the sub-stage condenser iris decreases the resolution of the particle and increases the depth of field over which other objects may interfere with the effect seen.

  7. Phase telescope - Wikipedia

    en.wikipedia.org/wiki/Phase_telescope

    The phase telescope/Bertrand lens is inserted into the microscope in place of an eyepiece to move the intermediate image plane to a point where it can be observed. Phase telescopes are primarily used for aligning the optical components required for Köhler illumination and phase contrast microscopy.

  8. Critical illumination - Wikipedia

    en.wikipedia.org/wiki/Critical_illumination

    Critical illumination acts to form an image of the light source on the specimen to illuminate it. [2] This image is formed by the condenser or collector lens. This illumination is bright but not always even, as any structure in the light source (for example the filament of a light bulb) will be visible in the

  9. Dark-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Dark-field_microscopy

    In optical microscopes a darkfield condenser lens must be used, which directs a cone of light away from the objective lens. To maximize the scattered light-gathering power of the objective lens, oil immersion is used and the numerical aperture (NA) of the objective lens must be less than 1.0. Objective lenses with a higher NA can be used but ...