Search results
Results From The WOW.Com Content Network
Proceq SA of Switzerland is a technology company in the nondestructive testing space. The company name Proceq is taken from a combination of the words “processes” and “equipment”. The main focus is on imaging solutions for non destructive testing of concrete structures, metal hardness testing, paper roll hardness testing and
A procedure for ultrasonic testing is outlined in ASTM C597 - 09. [9] In India, till 2018 ultrasonic testing was conducted according to IS 13311-1992.From 2018, procedure and specification for Ultrasonic pulse velocity test is outlined in IS 516 Part 5:Non destructive testing of concrete Section 1:Ultrasonic Pulse Velocity Testing. This test ...
Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage. This method provides little indication of ...
BS 1881:204 Testing concrete. Recommendations on the use of electromagnetic covermeters; DGZfP:B2: Guideline “für Bewehrungsnachweis und Überdeckungsmessung bei Stahl- und Spannbeton” DIN 1045: Guideline Concrete, reinforced and prestressed concrete structures; ACI Concrete Practices Non Destructive testing 228.2R-2.51: Covermeters
Thermal Integrity Profiling (TIP) is a non-destructive testing method used to evaluate the integrity of concrete foundations. It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida.
The test hammer hits the concrete at a defined energy. Its rebound is dependent on the hardness of the concrete and is measured by the test equipment. By reference to a conversion chart, the rebound value can be used to determine the concrete's compressive strength. When conducting the test, the hammer should be held at right angles to the ...
Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration. ASTM Standard C1202-10. Standard Test Method for Surface Resistivity of Concrete's Ability to Resist Chloride Ion Penetration. Washington, D.C., USA: American Association of State Highway and Transportation Officials. 2011. AASHTO TP 95.
In a masonry cavity wall, there is usually a DPC in both the outer and inner wall. [8] In the outer wall it is normally 150 millimetres (5.9 in) to 200 mm (7.9 in) above ground level (the height of 2-3 brick courses). This allows rain to form puddles and splash up off the ground, without saturating the wall above DPC level.