When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    The tonometer tip rests on the cornea with a constant appositional force of one gram. When the sensor is subjected to a change in pressure, the electrical resistance is altered and the tonometer's computer calculates a change in pressure according to the change in resistance. A complete measurement cycle requires about eight seconds of contact ...

  3. Schiøtz tonometer - Wikipedia

    en.wikipedia.org/wiki/Schiøtz_tonometer

    The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.

  4. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Goldmann Applanation Tonometer attached with Slit lamp biomicroscope Goldmann Applanation Tonometer is an instrument that is based on Imbert-Fick law . It is considered to be the gold standard instrument for measurement of Intraocular pressure (IOP).

  5. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    A patient in front of a tonometer. Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .

  6. List of instruments used in ophthalmology - Wikipedia

    en.wikipedia.org/wiki/List_of_instruments_used...

    to correct refractive errors of the eye; not invasive Contact lenses: to correct refractive errors of the eye; a little invasive Phoropter: used in refraction testing Tonometers: used to determine the intraoccular pressure (IOP) - useful in glaucoma; video link for various types of tonometers. Speculum: to keep the eyes open during any operation

  7. Imbert-Fick law - Wikipedia

    en.wikipedia.org/wiki/Imbert-Fick_law

    Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.

  8. Electrooculography - Wikipedia

    en.wikipedia.org/wiki/Electrooculography

    To measure eye movement, pairs of electrodes are typically placed either above and below the eye or to the left and right of the eye. If the eye moves from center position toward one of the two electrodes, this electrode "sees" the positive side of the retina and the opposite electrode "sees" the negative side of the retina.

  9. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.