When.com Web Search

  1. Ads

    related to: thermal energy efficiency calculator for kids table 2 chairs ikea singapore

Search results

  1. Results From The WOW.Com Content Network
  2. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: = Where: = rate of heat transfer [W] = heat transfer surface area [m 2]

  3. Thermal efficiency - Wikipedia

    en.wikipedia.org/wiki/Thermal_efficiency

    The role of a heat exchanger is to transfer heat between two mediums, so the performance of the heat exchanger is closely related to energy or thermal efficiency. [11] A counter flow heat exchanger is the most efficient type of heat exchanger in transferring heat energy from one circuit to the other [ citation needed ] .

  4. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    A realistic indication of energy efficiency over an entire year can be achieved by using seasonal COP or seasonal coefficient of performance (SCOP) for heat. Seasonal energy efficiency ratio (SEER) is mostly used for air conditioning. SCOP is a new methodology which gives a better indication of expected real-life performance of heat pump ...

  5. Energy factor - Wikipedia

    en.wikipedia.org/wiki/Energy_factor

    The energy factor metric only applies to residential water heaters, which are currently defined by fuel, type, and input capacity. [5] Generally, the EF number represents the thermal efficiency of the water heater as a percentage, since it is an average of the ratio of the theoretical heat required to raise the temperature of water drawn to the amount of energy actually consumed by the water ...

  6. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    90–95% (multiply by the energy efficiency of electricity generation to compare with other water-heating systems) Electric heater: Electrical to thermal ~100% (essentially all energy is converted into heat, multiply by the energy efficiency of electricity generation to compare with other heating systems) Others: Firearm: Chemical to kinetic

  7. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    For example, in winter it might be 2 °C outside and 20 °C inside, making a temperature difference of 18 °C or 18 K. If the material has an R-value of 4, it will lose 0.25 W/(°C⋅m 2). With an area of 100 m 2, the heat energy being lost is 0.25 W/(K⋅m 2) × 18 °C × 100 m 2 = 450 W.

  8. Solar gain - Wikipedia

    en.wikipedia.org/wiki/Solar_gain

    The shading coefficient (SC) is a measure of the radiative thermal performance of a glass unit (panel or window) in a building.It is defined as the ratio of solar radiation at a given wavelength and angle of incidence passing through a glass unit to the radiation that would pass through a reference window of frameless 3 millimetres (0.12 in) Clear Float Glass. [3]

  9. Energy conservation - Wikipedia

    en.wikipedia.org/wiki/Energy_conservation

    Measurable energy conservation and efficiency gains in the 1980s led to the 1987 Energy Security Report to the President (DOE, 1987) that "the United States uses about 29 quads less energy in a year today than it would have if our economic growth since 1972 had been accompanied by the less- efficient trends in energy use we were following at ...

  1. Ad

    related to: thermal energy efficiency calculator for kids table 2 chairs ikea singapore