When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Liquid rheostat - Wikipedia

    en.wikipedia.org/wiki/Liquid_rheostat

    A liquid rheostat or water rheostat [1] or salt water rheostat is a type of variable resistor. This may be used as a dummy load or as a starting resistor for large slip ring motors. In the simplest form it consists of a tank containing brine or other electrolyte solution, in which electrodes are submerged to create an electrical load .

  3. Float switch - Wikipedia

    en.wikipedia.org/wiki/Float_switch

    A float switch is a type of level sensor, a device used to detect the level of liquid within a tank. The switch may be used to control a pump, as an indicator, an alarm, or to control other devices. One type of float switch uses a mercury switch inside a hinged float. Another common type is a float that raises a rod to actuate a microswitch.

  4. Level sensor - Wikipedia

    en.wikipedia.org/wiki/Level_sensor

    Hydrostatic pressure level sensors are submersible or externally mounted pressure sensors suitable for measuring the level of corrosive liquids in deep tanks or water in reservoirs. Typically, fluid level is determined by the pressure at the bottom of the fluid containment (tank or reservoir); the pressure at the bottom, adjusted for the ...

  5. Industrial process control - Wikipedia

    en.wikipedia.org/wiki/Industrial_process_control

    The flow control into the tank would be cascaded off the level control. A further example is shown. If a control valve were used to hold level in a tank, the level controller would compare the equivalent reading of a level sensor to the level setpoint and determine whether more or less valve opening was necessary to keep the level constant.

  6. Level control valve - Wikipedia

    en.wikipedia.org/wiki/Level_control_valve

    A level control valve or altitude control valve is a type of valve that automatically responds to changes in the height of a liquid in some storage system. A common example is the set of ballcocks in a flush toilet, where each stage of the flush cycle is actuated by the emptying or filling of the tank. Another example is in reservoirs and other ...

  7. Water softening - Wikipedia

    en.wikipedia.org/wiki/Water_softening

    Brine draw: Water is directed through a jet pump, which pulls salt water from the brine tank, before the water and brine pass through the resin bed in the normal direction, if co-current, or in the reverse direction, if counter-current. [12] The output of this typically thirty-minute process is discarded through the drain hose.

  8. Dry running protection - Wikipedia

    en.wikipedia.org/wiki/Dry_running_protection

    Dry running protection, also known as dry-run protection or dry-running protection, is a type of protection mechanism to prevent a rotor, pump or stirrer shaft from operating without any medium added, as the bearing and shaft seal might be damaged if the motor is run while dry. [1]

  9. Water level (device) - Wikipedia

    en.wikipedia.org/wiki/Water_level_(device)

    The water level at each end of the tube will be at the same elevation, whether the two ends are adjacent or far apart, so a line between them will be horizontal at its midpoint and a shed base, building foundation or similar structure laid out using several such lines will be "horizontal" within building tolerances on any scale over which use ...