The rad is a unit of absorbed radiation dose, defined as 1 rad = 0.01 Gy = 0.01 J/kg. [1] It was originally defined in CGS units in 1953 as the dose causing 100 ergs of energy to be absorbed by one gram of matter.
Geiger-Müller counter with dual counts/dose rate display measuring a "point source". The dose per count is known for this specific instrument by calibration. The count rates of cps and cpm are generally accepted and convenient practical rate measurements. They are not SI units, but are de facto radiological units of measure in widespread use.
For such purposes, doses should be evaluated in terms of absorbed dose (in gray, Gy), and where high-LET radiations (e.g., neutrons or alpha particles) are involved, an absorbed dose, weighted with an appropriate RBE, should be used" Radiation weighting factors are largely based on the RBE of radiation for stochastic health risks. However, for ...
It is often indicated in micrograys per hour (μGy/h) [1] or as an equivalent dose rate Ḣ T in rems per hour (rem/hr) or sieverts per hour (Sv/h). [ 2 ] [ 3 ] Dose and dose rate are used to measure different quantities [ 1 ] in the same way that distance and speed are used to measure different quantities.
Recognized effects of higher acute radiation doses are described in more detail in the article on radiation poisoning.Although the International System of Units (SI) defines the sievert (Sv) as the unit of radiation dose equivalent, chronic radiation levels and standards are still often given in units of millirems (mrem), where 1 mrem equals 1/1,000 of a rem and 1 rem equals 0.01 Sv.
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass.Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmful effects), and radiology (potential beneficial effects, for example in cancer treatment).
The deterministic effects that can lead to acute radiation syndrome only occur in the case of high doses (> ~10 rad or > 0.1 Gy) and high dose rates (> ~10 rad/h or > 0.1 Gy/h). A model of deterministic risk would require different weighting factors (not yet established) than are used in the calculation of equivalent and effective dose.
Committed equivalent dose, H T (t) is the time integral of the equivalent dose rate in a particular tissue or organ that will be received by an individual following intake of radioactive material into the body by a Reference Person, where s is the integration time in years. [13]