When.com Web Search

  1. Ads

    related to: transformer full load current calculation for motor

Search results

  1. Results From The WOW.Com Content Network
  2. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  3. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

  4. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    After reaching the rated current of the HV side, all three instruments reading (Voltmeter, Ammeter, and wattmeter readings) are recorded. The ammeter reading gives the primary equivalent of full load current I L. As the voltage applied for full load current in short circuit test on transformer is quite small compared to the rated primary ...

  5. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    An induction motor draws very high starting current during its acceleration to full rated speed, typically 6 to 10 times the full load current. Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque.

  6. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    An induction motor draws very high starting current during its acceleration to full rated speed, typically 6 to 10 times the full load current. Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque.

  7. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    The induction motor stator's magnetic field is therefore changing or rotating relative to the rotor. This induces an opposing current in the rotor, in effect the motor's secondary winding. [28] The rotating magnetic flux induces currents in the rotor windings, [29] in a manner similar to currents induced in a transformer's secondary winding(s).

  8. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.

  9. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.