The pin index safety system uses a face seal between the cylinder valve and the associated yoke clamp. There are two holes in specific positions on the cylinder valve body below the outlet port , in positions associated with the gas mixture, which prevent connection of the cylinder to a yoke or pressure regulator with a mis-matched set of pins.
An open circuit SCBA typically has three main components: a high-pressure gas storage cylinder, (e.g., 2,216 to 5,500 psi (15,280 to 37,920 kPa), about 150 to 374 atmospheres), a pressure regulator, and a respiratory interface, which may be a mouthpiece, half mask or full-face mask, assembled and mounted on a framed carrying harness. [2]
A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. [citation needed] There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank.
A dilutor demand regulator draws ambient air into the mask through an orifice in the regulator, while concurrently being fed with pure oxygen through a demand valve in the regulator. For aeronautical use the size of the ambient air orifice is controlled by an aneroid valve operator and is directly proportional to atmospheric pressure. [ 12 ]
Medical use liquid oxygen airgas tanks are typically 2.4 MPa (350 psi). [citation needed] All equipment coming into contact with high pressure oxygen must be "oxygen clean" and "oxygen compatible", to reduce the risk of fire. [3] [4] "Oxygen clean" means the removal of any substance that could act as a source of ignition. "Oxygen compatible ...
Demand Valve Oxygen Therapy (DVOT) is a way of delivering high flow oxygen therapy using a device that only delivers oxygen when the patient breathes in and shuts off when they breathe out. DVOT is commonly used to treat conditions such as cluster headache , which affects up to four in 1000 people (0.4%), [ 1 ] [ 2 ] [ 3 ] and is a recommended ...
Medical oxygen storage tanks at the Royal Women's Hospital, Melbourne, Australia. Oxygen may be used for patients requiring supplemental oxygen via mask. Usually accomplished by a large storage system of liquid oxygen at the hospital which is evaporated into a concentrated oxygen supply, pressures are usually around 345–380 kPa (50.0–55.1 psi), [1] [2] or in the UK and Europe, 4–5 bar ...
Pulling down on one oxygen mask starts the oxygen supply for that mask only. The entire system can usually be reset in the cockpit or in some other location in the aircraft. [citation needed] A decentralized gaseous system, often called a pulse oxygen system, [4] is used on some modern airliners such as the Boeing 787. These systems have a ...