An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection. The term includes superconducting, solid-state and inductive devices. [2]
NTC thermistors can be used as inrush-current limiting devices in power supply circuits when added in series with the circuit being protected. They present a higher resistance initially, which prevents large currents from flowing at turn-on. As current continues to flow, NTC thermistors heat up, allowing higher current flow during normal operation.
An electrical ballast is a device placed in series with a load to limit the amount of current in an electrical circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps to limit the current through the tube, which would otherwise rise to a destructive level due to the negative differential resistance of the ...
It is known as a current-limiting diode (CLD) or current-regulating diode (CRD). Internal structure. It consists of an n-channel JFET with the gate shorted to the source, which functions like a two-terminal current limiter (analogous to a voltage-limiting Zener diode). It allows a current through it to rise to a certain value, but not higher.
Current limiting reactor. The main motive of using current limiting reactors is to reduce short-circuit currents so that circuit breakers with lower short circuit breaking capacity can be used. They can also be used to protect other system components from high current levels and to limit the inrush current when starting a large motor. [5]
The 1965 edition of the NEC, article 384-15 was the first reference to the circuit total limitation of panelboards. [1] As of 2008, the location of this language is at Article 408.54 now titled "Maximum Number of Overcurrent Devices." Non-CTL panels have not been made by reputable manufacturers since 1965.
Limiting can refer to a range of treatments designed to limit the maximum level of a signal. Treatments in order of decreasing severity range from clipping, in which a signal is passed through normally but sheared off when it would normally exceed a certain threshold; soft clipping which squashes peaks instead of shearing them; a hard limiter, a type of variable-gain audio level compression ...