  1. Results From The WOW.Com Content Network
  2. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    A typical electrical generator rating plate contains the following parameters: [4] power rating is specified in terms of apparent power (KVA or MVA), since the exact power factor will be determined by the external factors; [5] power factor (PF) is the nominal power factor for other ratings; usually PF = 0.8; [5]

  3. Voltage optimisation - Wikipedia

    en.wikipedia.org/wiki/Voltage_optimisation

    The latter includes power that is unusable, so a power factor of 1 is desirable. A low power factor would mean that the electricity supplier would effectively supply more energy than the consumer's bill would indicate, and suppliers are allowed to charge for low power factors. Reactive power is the name given to unusable power. It does no work ...

  4. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...

  5. Grid code - Wikipedia

    en.wikipedia.org/wiki/Grid_code

    Typically, a grid code will specify the required behavior of a connected generator during system disturbances. These include voltage regulation , power factor limits and reactive power supply, response to a system fault (e.g. short-circuit ), response to frequency changes on the grid, and requirement to " ride through " short interruptions of ...

  6. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    Three power factor scenarios are shown, where (a) the line serves an inductive load so the current lags receiving end voltage, (b) the line serves a completely real load so the current and receiving end voltage are in phase, and (c) the line serves a capacitive load so the current leads receiving end voltage.

  7. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Adjustments in power output for a particular primer mover and generator combination are made by slowly raising the droop curve by increasing the spring pressure on a centrifugal governor or by an engine control unit adjustment, or the analogous operation for an electronic speed governor. All units to be connected to a grid should have the same ...

  8. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    the power network equipment is designed for a narrow voltage range, so is the power consuming equipment on the customer side. Operation outside of this range will cause the equipment to fail; reactive power causes heating in the generators and the transmission lines, thermal limits will require restricting the production and the flow of real ...

  9. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage. The resistive/reactive combination load banks are used to test the engine generator set at its rated power factor. In most cases this is 0.8 power factor ...