Search results

  1. Results From The WOW.Com Content Network
  2. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  3. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...

  4. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  5. Air flow meter - Wikipedia

    en.wikipedia.org/wiki/Air_flow_meter

    An air flow meter is a device similar to an anemometer that measures air flow, i.e. how much air is flowing through a tube. It does not measure the volume of the air passing through the tube, it measures the mass of air flowing through the device per unit time, though Thus air flow meters are simply an application of mass flow meters for the ...

  6. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    is the gross amount of air circulated through the fan (or ventilation system) [m 3 /s] There are various sub-definitions of SFP for different specific applications, including SFP e (building energy performance calculations), SFP v (for performance verification tests), SFP i (individual fan), SFP AHU (air handling unit), SFP FCU (fan coil unit ...

  7. Airwatt - Wikipedia

    en.wikipedia.org/wiki/Airwatt

    [1] [2] This measurement reflects the energy per unit time of the air flowing through the vacuum's opening, which correlates to the electrical energy (wattage) supplied through the power cable. [ 3 ] The airwatt is a valuable measurement of vacuum cleaner motor efficiency because it represents the power carried by the fluid flow (in the case of ...

  8. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  9. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. [32] (Minisplit ...