When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power-factor correction increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the ...

  3. Inductance - Wikipedia

    en.wikipedia.org/wiki/Inductance

    This equation also is a direct consequence of the linearity of Maxwell's equations. It is helpful to associate changing electric currents with a build-up or decrease of magnetic field energy. The corresponding energy transfer requires or generates a voltage.

  4. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    For instance, a power factor of 0.68 means that only 68 percent of the total current supplied (in magnitude) is actually doing work; the remaining current does no work at the load. Power Factor is very important in Power sector substations. Form the national grid the sub sectors are required to have minimum amount of power factor.

  5. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    However, the maximum power theorem does not apply to its "downstream" connection. That connection is an impedance bridging connection; it emulates a high-voltage, low-resistance source to maximize efficiency. On the power grid the overall load is usually inductive. Consequently, power factor correction is most commonly achieved with banks of ...

  6. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source. Real power is the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the average product of current and voltage.

  7. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    When the load current exceeds the capability of the generator to supply both magnetization reactive power and load power the generator will immediately cease to produce power. The load must be removed and the induction generator restarted with either an external DC motor or if present, residual magnetism in the core. [2]

  8. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    For economic and other considerations, power systems are rarely power factor corrected to unity power factor. [46] Power capacitor application with harmonic currents requires power system analysis to avoid harmonic resonance between capacitors and transformer and circuit reactances. [47] Common bus power factor correction is recommended to ...

  9. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    To avoid magnetic inrush, only for transformers with an air gap in the core, the inductive load needs to be synchronously connected near a supply voltage peak, in contrast with the zero-voltage switching, which is desirable to minimize sharp-edged current transients with resistive loads such as high-power heaters.