When.com Web Search

  1. Ads

    related to: hooking two honda generators together side by side manual download free

Search results

  1. Results From The WOW.Com Content Network
  2. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    The sequence of events is similar for manual or automatic synchronization. The generator is brought up to approximate synchronous speed by supplying more energy to its shaft - for example, opening the valves on a steam turbine, opening the gates on a hydraulic turbine, or increasing the fuel rack setting on a diesel engine.

  3. Synchroscope - Wikipedia

    en.wikipedia.org/wiki/Synchroscope

    If two electrical networks operating at two different phase angles were to be connected to each other, a fault similar to a short circuit would occur, presenting a hazard of damage to the generator or other equipment. The position (as opposed to rotation) of the pointer on a synchroscope indicates the phase angle between the two systems.

  4. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    the power network equipment is designed for a narrow voltage range, so is the power consuming equipment on the customer side. Operation outside of this range will cause the equipment to fail; reactive power causes heating in the generators and the transmission lines, thermal limits will require restricting the production and the flow of real ...

  5. List of Honda engines - Wikipedia

    en.wikipedia.org/wiki/List_of_Honda_engines

    1997–2005 3.2 L C32B - NSX (manual transmission from 1997) J-series - 60° SOHC Started production in 1996 debuting in the 1997 Acura 3.0CL. 1998–2003 2.5 L J25A JDM only engine debuted in 1999 Honda Inspire/Saber 25V.

  6. Swing equation - Wikipedia

    en.wikipedia.org/wiki/Swing_equation

    The electric torque T e corresponds to the net air-gap power in the machine and thus accounts for the total output power of the generator plus I 2 R losses in the armature winding. The angular position θ is measured with a stationary reference frame. Representing it with respect to the synchronously rotating frame gives:

  7. American Honda Motor Company - Wikipedia

    en.wikipedia.org/wiki/American_Honda_Motor_Company

    The American Honda Motor Company, Inc. (sometimes abbreviated as AHM) is the North American subsidiary of Japanese Honda Motor Company.Founded in 1959, the company combines product sales, service and coordinating functions of Honda in North America, and is responsible for distribution, marketing and sales of Honda and Acura brand automobiles, Honda Powersports products (motorcycles, scooters ...

  8. Shunt generator - Wikipedia

    en.wikipedia.org/wiki/Shunt_generator

    Generator separately excited by battery Self exciting generators Series on left, shunt on right. A shunt generator is a type of electric generator in which field winding and armature winding are connected in parallel, and in which the armature supplies both the load current and the field current for the excitation (generator is therefore self excited).

  9. Polyphase system - Wikipedia

    en.wikipedia.org/wiki/Polyphase_system

    One voltage cycle of a three-phase system. A polyphase system (the term coined by Silvanus Thompson) is a means of distributing alternating-current (AC) electrical power that utilizes more than one AC phase, which refers to the phase offset value (in degrees) between AC in multiple conducting wires; phases may also refer to the corresponding terminals and conductors, as in color codes.