When.com Web Search

  1. Ad

    related to: boiler turndown calculation spreadsheet

Search results

  1. Results From The WOW.Com Content Network
  2. Turndown ratio - Wikipedia

    en.wikipedia.org/wiki/Turndown_ratio

    Boiler turndown ratio is the ratio of maximum heat output to the minimum level of heat output at which the boiler will operate efficiently or controllably. Many boilers are designed to operate at a variety of output levels. As the desired temperature/pressure point is approached, the heat source is progressively turned down.

  3. Pinch analysis - Wikipedia

    en.wikipedia.org/wiki/Pinch_analysis

    The most detailed explanation of the techniques is by Linnhoff et al. (1982), Shenoy (1995), Kemp (2006) and Kemp and Lim (2020), while Smith (2005) includes several chapters on them. Both detailed and simplified (spreadsheet) programs are now available to calculate the energy targets. See Pinch Analysis Software below.

  4. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    This committee put in the form work for the first edition of the ASME Boiler Code - Rules for the Construction of Stationary Boilers and for the Allowable Working Pressures, which was issued in 1914 and published in 1915. [5] The first edition of the Boiler and Pressure Vessel Code, known as the 1914 edition, was a single 114-page volume.

  5. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Boilers have a turndown ratio which is the ratio of the maximum power output to the minimum power output for which combustion can be maintained. If the control system determines that the demand falls below the minimum power output, then the boiler will cycle off until the water temperature has fallen, and then will reignite and heat the water.

  6. NTU method - Wikipedia

    en.wikipedia.org/wiki/NTU_Method

    The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...

  7. Annual fuel utilization efficiency - Wikipedia

    en.wikipedia.org/wiki/Annual_fuel_utilization...

    The annual fuel utilization efficiency (AFUE; pronounced 'A'-'Few' or 'A'-'F'-'U'-'E') is a thermal efficiency measure of space-heating furnaces and boilers.The AFUE differs from the true 'thermal efficiency' in that it is not a steady-state, peak measure of conversion efficiency, but instead attempts to represent the actual, season-long, average efficiency of that piece of equipment ...

  8. Logarithmic mean temperature difference - Wikipedia

    en.wikipedia.org/wiki/Logarithmic_mean...

    Assume heat transfer [2] is occurring in a heat exchanger along an axis z, from generic coordinate A to B, between two fluids, identified as 1 and 2, whose temperatures along z are T 1 (z) and T 2 (z).

  9. ISASMELT - Wikipedia

    en.wikipedia.org/wiki/ISASMELT

    The high heat transfer rate means that the Fluxflow boiler is relatively compact compared with conventional waste heat boilers and the rapid cooling of the waste gas limits the formation of sulfur trioxide ("SO 3 "), which in the presence of water forms sulfuric acid that can cause corrosion of cool surfaces. [43] Mount Isa copper smelter in 2002.

  1. Ad

    related to: boiler turndown calculation spreadsheet