Search results
Results From The WOW.Com Content Network
One computational method which can be used to calculate IV estimates is two-stage least squares (2SLS or TSLS). In the first stage, each explanatory variable that is an endogenous covariate in the equation of interest is regressed on all of the exogenous variables in the model, including both exogenous covariates in the equation of interest and ...
Flow injection analysis (FIA) was first described by Ruzicka and Hansen in Denmark in 1974 and Stewart and coworkers in United States in 1979. FIA is a popular, simple, rapid, and versatile technique which is a well-established position in modern analytical chemistry, and widespread application in quantitative chemical analysis. [6]
Gravimetric analysis describes a set of methods used in analytical chemistry for the quantitative determination of an analyte (the ion being analyzed) based on its mass. The principle of this type of analysis is that once an ion's mass has been determined as a unique compound, that known measurement can then be used to determine the same analyte's mass in a mixture, as long as the relative ...
A normal experiment may involve 1–10 mL solution with an analyte concentration between 1 and 10 mmol/L. More advanced voltammetric techniques can work with microliter volumes and down to nanomolar concentrations. Chemically modified electrodes are employed for the analysis of organic and inorganic samples.
A list of chemical analysis methods with acronyms. A. Atomic absorption ... Gas chromatography-mass ... Analytical chemistry; List of materials analysis methods
Desorption electrospray ionization (DESI) is an ambient ionization technique that can be coupled to mass spectrometry (MS) for chemical analysis of samples at atmospheric conditions. Coupled ionization sources-MS systems are popular in chemical analysis because the individual capabilities of various sources combined with different MS systems ...
There are many mass/charge separation and isolation methods but the most commonly used is the mass instability mode in which the RF potential is ramped so that the orbit of ions with a mass a > b are stable while ions with mass b become unstable and are ejected on the z-axis onto a detector. There are also non-destructive analysis methods.
Static SIMS is the process involved in surface atomic monolayer analysis, or surface molecular analysis, usually with a pulsed ion beam and a time of flight mass spectrometer, while dynamic SIMS is the process involved in bulk analysis, closely related to the sputtering process, using a DC primary ion beam and a magnetic sector or quadrupole ...