The cable connectors and sockets are keyed and colour-coded, according to the voltage range and frequency used; common colours for 50–60 Hz AC power are yellow for 100–130 volts, blue for 200–250 volts, and red for 380–480 volts.
Most post-war European thermionic valve (vacuum tube) manufacturers have used the Mullard–Philips tube designation naming scheme. Special quality variants may have the letter "S" appended, or the device description letters may be swapped with the numerals (e.g. an E82CC is a special quality version of an ECC82)
For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...
Mullard initially handled semiconductor naming by using the "O" heater code (shifting "Cold Cathode" to a code of "Z"). The second letter broadly indicated the type of device, roughly following the tube designation, without indicating the semiconductor material: A low-power semiconductor diode, e.g. OA7
Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.
The Roots blower is one example of a vacuum pump. A vacuum pump is a type of pump device that draws gas particles from a sealed volume in order to leave behind a partial vacuum. The first vacuum pump was invented in 1650 by Otto von Guericke, and was preceded by the suction pump, which dates to antiquity. [1]
For those Cases that have been adopted will appear in the appropriate Code Cases book: "Boilers and Pressure Vessels" and "Nuclear Components." [9] Codes Cases are usually intended to be incorporated in the Code in a later edition. When it is used, the Code Case specifies mandatory requirements which must be met as it would be with the Code.
Where two voltages are given below separated by "/", the first is the root-mean-square voltage between a phase and the neutral connector, whereas the second is the corresponding root-mean-square voltage between two phases (exception: the category shown below called "One Phase", where 240 V is the root-mean-square voltage between the two legs of a split phase).