Rosemount Inc. is a subsidiary of Emerson Electric Company. Its headquarters is located in Shakopee, Minnesota , where they manufacture measurement instrumentation such as pressure, temperature, level, DP flow, and wireless, as well as analytical and detection instrumentation for gas analysis, liquid analysis, combustion measurement and flame ...
A DP cell is a device that measures the differential pressure between two inputs. [1]Example: To measure the pressure difference between a container (or vessel) and the surrounding atmosphere, you may connect 'Hi' port of the DP-cell to a fitting that enters the vessel, using suitable tubing.
A pressure switch is a form of switch that operates an electrical contact when a certain set fluid pressure has been reached on its input. The switch may be designed to make contact either on pressure rise or on pressure fall. Pressure switches are widely used in industry to automatically supervise and control systems that use pressurized fluids.
The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.
Differential pressure is the difference in pressure between two points. Differential pressure sensors are used to measure many properties, such as pressure drops across oil filters or air filters, fluid levels (by comparing the pressure above and below the liquid) or flow rates (by measuring the change in pressure across a restriction ...
The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.
The low differential voltage, about 350 mV, causes LVDS to consume very little power compared to other signaling technologies. At 2.5 V supply voltage the power to drive 3.5 mA becomes 8.75 mW, compared to the 90 mW dissipated by the load resistor for an RS-422 signal. Logic levels: [1]
Orifice plate showing vena contracta. An orifice plate is a thin plate with a hole in it, which is usually placed in a pipe. When a fluid (whether liquid or gaseous) passes through the orifice, its pressure builds up slightly upstream of the orifice [1] but as the fluid is forced to converge to pass through the hole, the velocity increases and the fluid pressure decreases.