Search results
Results From The WOW.Com Content Network
Schematic diagram of a Michelson interferometer, configured for FTIR. In a Michelson interferometer adapted for FTIR, light from the polychromatic infrared source, approximately a black-body radiator, is collimated and directed to a beam splitter. Ideally 50% of the light is refracted towards the fixed mirror and 50% is transmitted towards the ...
FTIR mode Sample preparation Schematic diagram Transmission FTIR: Transmission mode is the most widely used FTIR technique in geoscience due to its high analysis speed and cost-efficient characteristics. [4] The sample, either a rock or a mineral, is cut into a block and polished on both sides until a thin (typically 300 to 15 μm) wafer is ...
The schematic representation of a nano-FTIR system with a broadband infrared source. Nano-FTIR (nanoscale Fourier transform infrared spectroscopy) is a scanning probe technique that utilizes as a combination of two techniques: Fourier transform infrared spectroscopy (FTIR) and scattering-type scanning near-field optical microscopy (s-SNOM).
This simple scheme in fact describes how some spectrometers work. Fourier-transform spectroscopy is a less intuitive way to get the same information. Rather than allowing only one wavelength at a time to pass through to the detector, this technique lets through a beam containing many different wavelengths of light at once, and measures the ...
A common laboratory instrument that uses this technique is a Fourier transform infrared (FTIR) spectrometer. Two-dimensional IR is also possible as discussed below. The infrared portion of the electromagnetic spectrum is usually divided into three regions; the near-, mid- and far-infrared, named for their relation to the visible spectrum.
Schematic of a 2D IR spectrum. The red circles correspond to bleaching of the ground state. The blue circles correspond to absorption of the excited state. The smaller off-diagonal circles to coupling between the two states. The linear absorption (FTIR) spectrum is indicated above the 2D IR spectrum.
Diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) [1] is an infrared spectroscopy sampling technique used on powder samples without prior preparation. The sample is added to a sample cup and the data is collected on the bulk sample.
Atomic force microscope inside a FTIR spectrometer with the optical interface. The earliest measurements combining AFM with infrared spectroscopy were performed in 1999 by Hammiche et al. at the University of Lancaster in the United Kingdom, [1] in an EPSRC-funded project led by M Reading and H M Pollock.