Search results
Results From The WOW.Com Content Network
Rosemount Inc. is a subsidiary of Emerson Electric Company. Its headquarters is located in Shakopee, Minnesota , where they manufacture measurement instrumentation such as pressure, temperature, level, DP flow, and wireless, as well as analytical and detection instrumentation for gas analysis, liquid analysis, combustion measurement and flame ...
A DP cell is a device that measures the differential pressure between two inputs. [1]Example: To measure the pressure difference between a container (or vessel) and the surrounding atmosphere, you may connect 'Hi' port of the DP-cell to a fitting that enters the vessel, using suitable tubing.
A rising pressure in the vessel results in the PCV opening to feed more gas forward. If the pressure continues to rise some controllers then act to open a second PCV that feeds excess gas to the flare system. The pressure transmitter is configured to provide warning alarms (PAL and PAH) if the pressure exceeds set high and low limits.
Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below: Obstruction type (differential pressure or variable area) Inferential (turbine type) Electromagnetic
The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.
Pressure sensors can alternatively be called pressure transducers, pressure transmitters, pressure senders, pressure indicators, piezometers and manometers, among other names. Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area.
For instance FIC045 means it is the Flow Indicating Controller in control loop 045. This is also known as the "tag" identifier of the field device, which is normally given to the location and function of the instrument. The same loop may have FT045 - which is the flow transmitter in the same loop.
The meter is "read" as a differential pressure head in cm or inches of water. Video of a Venturi meter used in a lab experiment Idealized flow in a Venturi tube. The Venturi effect is the reduction in fluid pressure that results when a moving fluid speeds up as it flows from one section of a pipe to a smaller section.