When.com Web Search

  1. Ad

    related to: solar load calculation excel worksheet

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  3. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared exchanges from the sky. The concept of T sol-air was thus introduced to enable these parameters to be included within an improved calculation. The following formula results:

  4. Sensitivity analysis of an EnergyPlus model - Wikipedia

    en.wikipedia.org/wiki/Sensitivity_analysis_of_an...

    OpenStudio Analysis Framework and Spreadsheet: [9] A front-end for the OpenStudio Server, allowing for users to create large-scale cloud analyses using OpenStudio measures. SALib : [ 10 ] A Python library for general sensitivity analysis, which can be used with user-defined scripts to run EnergyPlus and extract results.

  5. Panel generation factor - Wikipedia

    en.wikipedia.org/wiki/Panel_generation_factor

    Panel generation factor (PGF) [1] is used while calculating the size of solar photovoltaic cells. It is a varying factor depending upon the climate of the site location (depending upon global geographic location). For example, in Thailand it is 3.43, in EU countries it is 2.93, etc. This factor is used in calculation of "Total Watt-Peak Rating ...

  6. Load profile - Wikipedia

    en.wikipedia.org/wiki/Load_Profile

    Graphs by hour of California's total electric load, the total load less solar and wind power (known as the duck curve) and solar power output. Data is for October 22, 2016, a day when the wind power output was low and steady throughout the day. In electrical engineering, a load profile is a graph of the variation in the electrical load versus ...

  7. Solar-cell efficiency - Wikipedia

    en.wikipedia.org/wiki/Solar-cell_efficiency

    By increasing the resistive load on an irradiated cell continuously from zero (a short circuit) to a very high value (an open circuit) one can determine the maximum power point, the point that maximizes V×I; that is, the load for which the cell can deliver maximum electrical power at that level of irradiation. (The output power is zero in both ...

  8. Cost of electricity by source - Wikipedia

    en.wikipedia.org/wiki/Cost_of_electricity_by_source

    The levelized cost of electricity (LCOE) is a metric that attempts to compare the costs of different methods of electricity generation consistently. Though LCOE is often presented as the minimum constant price at which electricity must be sold to break even over the lifetime of the project, such a cost analysis requires assumptions about the value of various non-financial costs (environmental ...

  9. Pinch analysis - Wikipedia

    en.wikipedia.org/wiki/Pinch_analysis

    HeatIT - Free (light) version of Pinch Analysis software that runs in Excel - developed by Pinchco, a consultancy company offering expert advice on energy related matters; Simulis Pinch - Tool from ProSim SA that can be used directly in Excel and that is dedicated to the diagnosis and the energy integration of the processes.