When.com Web Search

  1. Ads

    related to: interlock kits for home generators natural gas

Search results

  1. Results From The WOW.Com Content Network
  2. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    Early generator interlock kits consisted of two sliding steel or plastic (depending on the brand) plates held together by three bolts and installed on the front cover of the home's breaker panel, however, some models made by Eaton (formerly Cutler-Hammer) and Siemens for panels manufactured by them install on the adjacent circuit breakers themselves and consist of a sliding arm for breakers ...

  3. Interlock (engineering) - Wikipedia

    en.wikipedia.org/wiki/Interlock_(engineering)

    An interlock device is designed to allow a generator to provide backup power in such a way that it (a) prevents main and generator power to be connected at the same time, and (b) allows circuit breakers to operate normally without interference in the event of an overload condition. Most interlock devices for electrical systems employ a ...

  4. Dispatchable generation - Wikipedia

    en.wikipedia.org/wiki/Dispatchable_generation

    Hydroelectric power plants can often dispatch in tens of seconds to minutes, and natural gas power plants can generally dispatch in tens of minutes. For example, the 1,728 MW Dinorwig pumped storage power plant can reach full output in 16 seconds. [4] Gas turbine (Brayton cycle) thermal plants

  5. Low voltage ride through - Wikipedia

    en.wikipedia.org/wiki/Low_voltage_ride_through

    Many generator designs use electric current flowing through windings to produce the magnetic field on which the motor or generator operates. This is in contrast to designs that use permanent magnets to generate this field instead. Such devices may have a minimum working voltage, below which the device does not work correctly, or does so at ...

  6. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. It works by controlling the rate of power ...

  7. Ravenswood Generating Station - Wikipedia

    en.wikipedia.org/wiki/Ravenswood_generating_station

    It is located on the Ravenswood site, consisting of Units 1, 2, 3 and 4, as well as several small gas turbines (GTs), and an oil depot. The site overall produces about 2,500 MW, or approximately 20% of New York City's current energy consumption. [15] [16] In 2011, Big Allis burned 97% natural gas, 3% oil (used as backup fuels).