When.com Web Search

  1. Ads

    related to: spin echo vs gradient mri machine

Search results

  1. Results From The WOW.Com Content Network
  2. Spin echo - Wikipedia

    en.wikipedia.org/wiki/Spin_echo

    Fast spin echo (RARE, FAISE or FSE [10] [11] [12]), also called turbo spin echo (TSE) is an MRI sequence that results in fast scan times. In this sequence, several 180 refocusing radio-frequency pulses are delivered during each echo time (TR) interval, and the phase-encoding gradient is briefly switched on between echoes. [ 13 ]

  3. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    Modern 3 Tesla clinical MRI scanner.. Magnetic resonance imaging (MRI) is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels ...

  4. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to generate pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves to form images of the organs in the body.

  5. Gradient echo - Wikipedia

    en.wikipedia.org/wiki/Gradient_echo

    Gradient echo is a magnetic resonance imaging (MRI) sequence that has wide variety of applications, from magnetic resonance angiography to perfusion MRI and diffusion MRI. Rapid imaging acquisition allows it to be applied to 2D and 3D MRI imaging.

  6. MRI pulse sequence - Wikipedia

    en.wikipedia.org/wiki/MRI_pulse_sequence

    When the spins are rephased, they become coherent, and thus signal (or "echo") is generated to form images. Unlike spin echo, gradient echo does not need to wait for transverse magnetisation to decay completely before initiating another sequence, thus it requires very short repetition times (TR), and therefore to acquire images in a short time.

  7. Fast low angle shot magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Fast_low_angle_shot...

    The generic FLASH technique emerges as a gradient echo sequence which combines a low-flip angle radio-frequency excitation of the NMR signal (recorded as a spatially encoded gradient echo) with a rapid repetition of the basic sequence. The repetition time is usually much shorter than the typical T1 relaxation time of the protons in biologic ...

  8. k-space in magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/K-space_in_magnetic...

    The only difference between the MRI k-space and the NMR time domain is that a gradient G is present in MRI data acquisition, but is absent in NMR data acquisition. As a result of this difference, the NMR FID signal and the MRI spin-echo signal take different mathematical forms:

  9. Real-time MRI - Wikipedia

    en.wikipedia.org/wiki/Real-time_MRI

    While spoiled FLASH sequences offer spin density or T1 contrast, versions with refocused or fully balanced gradients provide access to T2/T1 contrast. The choice of the gradient-echo time (e.g., in-phase vs opposed-phase conditions) further alters the representation of water and fat signals in the images and will allow for separate water/fat ...