Ultrasound is applied using a transducer or applicator that is in direct contact with the patient's skin. Gel is used on all surfaces of the head to reduce friction and assist transmission of the ultrasonic waves. Therapeutic ultrasound in physical therapy is alternating compression and rarefaction of sound waves with a frequency of 0.7 to 3.3 ...
Low-intensity pulsed ultrasound (LIPUS) is a technology that can be used for therapeutic purposes. It exploits low intensity and pulsed mechanical waves in order to induce regenerative and anti-inflammatory effects on biological tissues, such as bone, [ 1 ] cartilage, and tendon. [ 2 ]
HIFU therapy requires careful monitoring and so it is usually performed in conjunction with other imaging techniques. Pre-operative imaging, for instance CT and MRI, are usually used to identify general parameters of the target anatomy. Real-time imaging, on the other hand, is necessary for safe and accurate noninvasive targeting and therapy ...
Medical ultrasound includes diagnostic techniques (mainly imaging techniques) using ultrasound, as well as therapeutic applications of ultrasound. In diagnosis, it is used to create an image of internal body structures such as tendons, muscles, joints, blood vessels, and internal organs, to measure some characteristics (e.g., distances and velocities) or to generate an informative audible sound.
Ultrasound imaging deposits energy over a large area while therapeutic ultrasound focuses the energy on one target site. Focused ultrasound for intracrainial drug delivery is a non-invasive technique that uses high-frequency sound waves (focused ultrasound, or FUS) to disrupt tight junctions in the blood–brain barrier (BBB), allowing for increased passage of therapeutics into the brain.
A low intensity (ISPTA < 5 W/cm2) pulsed ultrasound (LIPSA) approach can exploit the mechanical properties of neoplastic cells to target them for destruction. Ultrasound applied at a frequency of 0.5–0.67 MHz for >20 ms causes selective disruption of a panel of breast, colon, and leukemia cancer cell models in suspension without significantly damaging healthy immune or red blood cells.
The enhanced circulation of blood that comes as a result of increased temperature from ultrasound parameters also allows for better diffusion of compounds. [1] While the intensity and duty cycle of the ultrasound are directly proportional to the corresponding thermal effects, surprisingly thermal effects are not a considerable mechanism for HFS ...
Ultrasound is defined by the American National Standards Institute as "sound at frequencies greater than 20 kHz". In air at atmospheric pressure, ultrasonic waves have wavelengths of 1.9 cm or less. Ultrasound can be generated at very high frequencies; ultrasound is used for sonochemistry at frequencies up to multiple hundreds of kilohertz.