Twiddler's syndrome is a malfunction of a pacemaker due to manipulation of the device and the consequent dislodging of the leads from their intended location. As the leads move, they stop pacing the heart and can cause strange symptoms such as phrenic nerve stimulation resulting in abdominal pulsing or brachial plexus stimulation resulting in rhythmic arm twitching. [1]
A Micro-dislodgement is a minimal displacement in the lead that is not visible in a chest X-ray, but has the ability to increase the capture threshold and eventually cause a loss of capture. [ 5 ] Lead dislodgement can cause sensing failure, which occurs when proper atrial or ventricular sensing is not achieved by the programming of the pacemaker.
[18] [20] Since its first discovery, there have been many definitions of pacemaker syndrome, and the understanding of the cause of pacemaker syndrome is still under investigation. In a general sense, pacemaker syndrome can be defined as the symptoms associated with right ventricular pacing relieved with the return of A-V and V-V synchrony. [17]
An ectopic pacemaker located in the atria is known as an atrial pacemaker and can cause the atrial contraction to be faster. [10] An ectopic pacemaker situated near the AV node and the septum is known as a junctional pacemaker. [11] The pacemaker that is operating in the ventricles is known as the ventricular. [12]
A pacemaker, also known as an artificial cardiac pacemaker, is an implanted medical device that generates electrical pulses delivered by electrodes to one or more of the chambers of the heart. Each pulse causes the targeted chamber(s) to contract and pump blood, [ 3 ] thus regulating the function of the electrical conduction system of the heart .
An artificial cardiac pacemaker (or artificial pacemaker, so as not to be confused with the natural cardiac pacemaker) or just pacemaker is an implanted medical device that generates electrical impulses delivered by electrodes to the chambers of the heart either the upper atria, or lower ventricles to cause the targeted chambers to contract and ...
A normal chest X-ray after placement of an ICD, showing the ICD generator in the upper left chest and the ICD lead in the right ventricle of the heart. Note the 2 opaque coils along the ICD lead. The process of implantation of an ICD system is similar to implantation of an artificial pacemaker. In fact, ICDs are composed of an ICD generator and ...
Chest tubes are also provided in right angle, trocar, flared, and tapered configurations for different drainage needs. As well, some chest tubes are coated with heparin to help prevent thrombus formation, though the effect of this is disputed. [16] Chest tube have an end hole (proximal, toward the patient) and a series of side holes.