When.com Web Search

  1. Ads

    related to: surface preparation for concrete slab path test for metal walls design

Search results

  1. Results From The WOW.Com Content Network
  2. Marcus' method - Wikipedia

    en.wikipedia.org/wiki/Marcus'_method

    Marcus's method is a structural analysis used in the design of reinforced concrete slabs.The method was developed by Henri Marcus and described in 1938 in Die Theorie elastischer Gewebe und ihre Anwendung auf die Berechnung biegsamer Platten. [1]

  3. Arching or compressive membrane action in reinforced concrete ...

    en.wikipedia.org/wiki/Arching_or_Compressive...

    Idealisation of arching action forces in laterally restrained slab. Arching or compressive membrane action (CMA) in reinforced concrete slabs occurs as a result of the great difference between the tensile and compressive strength of concrete. Cracking of the concrete causes a migration of the neutral axis which is accompanied by in-plane ...

  4. Load path analysis - Wikipedia

    en.wikipedia.org/wiki/Load_path_analysis

    The U* index represents the internal stiffness of every point within the structure. Consequently, the line connecting the highest U* values is the main load path. In other words, the main load path is the ridge line of the U* distribution (contour) [1] This method of analysis has been verified in physical experimentation. [3]

  5. Voided biaxial slab - Wikipedia

    en.wikipedia.org/wiki/Voided_biaxial_slab

    The overall mass of concrete can be reduced by 35–50% depending on the design, [1] as a consequence of reduced slab mass, as well as lower requirements for vertical structure and foundations. Biaxial slabs commonly span up to 20 metres at a thickness of around 500 mm. [ citation needed ] The added strength also reduces the acoustic ...

  6. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  7. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    (2) The thermal expansion coefficients of concrete and steel are so close (1.0 × 10 −5 to 1.5 × 10 −5 for concrete and 1.2 × 10 −5 for steel) that the thermal stress-induced damage to the bond between the two components can be prevented. (3) Concrete can protect the embedded steel from corrosion and high-temperature induced softening.

  8. Porosity - Wikipedia

    en.wikipedia.org/wiki/Porosity

    Porosity may take on several forms from interconnected micro-porosity, folds, and inclusions to macro porosity visible on the part surface. The end result of porosity is the creation of a leak path through the walls of a casting that prevents the part from holding pressure.

  9. Concrete slab - Wikipedia

    en.wikipedia.org/wiki/Concrete_slab

    A concrete slab is a common structural element of modern buildings, consisting of a flat, horizontal surface made of cast concrete. Steel- reinforced slabs, typically between 100 and 500 mm thick, are most often used to construct floors and ceilings, while thinner mud slabs may be used for exterior paving ( see below ).