  1. Results From The WOW.Com Content Network
  2. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Air circuit breakers—Rated current up to 6,300 A and higher for generator circuit breakers. Trip characteristics are often fully adjustable including configurable trip thresholds and delays. Usually electronically controlled, though some models are microprocessor controlled via an integral electronic trip unit. Often used for main power ...

  3. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    To prevent electric power distribution network damage, each station along the network is protected with circuit breakers or fuse cutouts which turn off power in the event of a short circuit. These protection solutions present a major problem when restoring power immediately following transient events, because repair crews need to manually reset ...

  4. Circuit breaker design pattern - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_design_pattern

    The Circuit Breaker is a design pattern commonly used in software development to improve system resilience and fault tolerance. Circuit breaker pattern can prevent cascading failures particularly in distributed systems. [1] In distributed systems, the Circuit Breaker pattern can be used to monitor service health and can detect failures dynamically.

  5. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases.

  6. Selectivity (circuit breakers) - Wikipedia

    en.wikipedia.org/wiki/Selectivity_(circuit_breakers)

    Selectivity, also known as circuit breaker discrimination, is the coordination of overcurrent protection devices so that a fault in the installation is cleared by the protection device located immediately upstream of the fault. The purpose of selectivity is to minimize the impact of a failure on the network.

  7. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    Further, this change is extremely rapid, before a circuit breaker can trip a few milliseconds later. (High-power circuit breakers are synchronized to the alternating current zero crossing to minimize arcing.) [citation needed] While the power is unstable during the fault, it is not completely disconnected.

  8. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Circuit breakers or RCDs to open/close the system based on relay and autorecloser commands; Batteries to provide power in case of power disconnection in the system; Communication channels to allow analysis of current and voltage at remote terminals of a line and to allow remote tripping of equipment.

  9. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...