When.com Web Search

  1. Ad

    related to: transformer full load current calculation for motor unit system of engine
    • Low Voltage Dry-Type

      Buy a general purpose transformer

      In stock low voltage transformers

    • Sell Surplus

      We Purchase New & Used Transformers

      Anywhere In North America.

    • Contact Us

      Get In touch with us

      We look forward to hearing from you

    • Padmount

      Request a quote for a padmount

      In stock padmount transformers

Search results

  1. Results From The WOW.Com Content Network
  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  3. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

  4. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    After reaching the rated current of the HV side, all three instruments reading (Voltmeter, Ammeter, and wattmeter readings) are recorded. The ammeter reading gives the primary equivalent of full load current I L. As the voltage applied for full load current in short circuit test on transformer is quite small compared to the rated primary ...

  5. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  6. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque. One basic method to reduce the starting current is with a reduced voltage autotransformer with taps at 50%, 65% and 80% of the applied line voltage; once the motor is started the ...

  7. Circle diagram - Wikipedia

    en.wikipedia.org/wiki/Circle_diagram

    The circle diagram can be drawn for alternators, synchronous motors, transformers, induction motors. The Heyland diagram is an approximate representation of a circle diagram applied to induction motors, which assumes that stator input voltage, rotor resistance and rotor reactance are constant and stator resistance and core loss are zero.

  8. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    This supplies the motor a lower voltage from the autotransformer. The lower voltage limits the input current to the initially stationary motor, which accelerates. The torque of the motor is also lowered. The motor continues to increase its speed until the motor torque and the load torque balance each other and a steady speed is achieved.

  9. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  1. Ad

    related to: transformer full load current calculation for motor unit system of engine