When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  3. BS 7671 - Wikipedia

    en.wikipedia.org/wiki/BS_7671

    In 1992, the IEE Wiring Regulations became British Standard BS 7671 so that the legal enforcement of their requirements was easier both with regard to the Electricity at Work regulations and from an international point of view. [4]

  4. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    To eliminate this confusion, the IEC decided to apply the term residual current device (RCD) to differential-current-operated ELCBs. Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current.

  5. IEC 60906-1 - Wikipedia

    en.wikipedia.org/wiki/IEC_60906-1

    IEC 60906-1-plug. IEC 60906-1 (IEC designation "Type N") [1] is an international standard designed "to provide a standard for a safe, compact and practical 16 A 250 V AC system of plugs and socket-outlets that could be accepted by many countries as their national standard, even if not in the near future."

  6. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    An example of a socket with neutral is the L21-30 (30 A) and the L21-20 (20 A) both of which have five pins (earth, neutral, and X, Y, Z phases). While some forms of power plugs and sockets are set by international standards, countries may have their own different standards and regulations.

  7. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    But as residual current devices mitigate this disadvantage, the TT earthing system has become much more attractive providing that all AC power circuits are RCD-protected. In some countries (such as the UK) TT is recommended for situations where a low impedance equipotential zone is impractical to maintain by bonding, where there is significant ...

  8. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    The addition is a 3 ⁄ 16-inch (4.8 mm) diameter round or U-shaped ground pin, 1 ⁄ 8 in (3.2 mm) longer than the power blades (so the device is grounded before the power is connected) and located from them by 1 ⁄ 4 in (6.4 mm) edge-to-edge or 15 ⁄ 32 in (11.9 mm) center-to-center.

  9. GOST 7396 - Wikipedia

    en.wikipedia.org/wiki/GOST_7396

    GOST 7396 (ГОСТ 7396 in Cyrillic) is a series of Soviet and later Russian standards that specify basic dimensions and safety requirements for power plugs and sockets used in Russia and other former Soviet Republics, as well as for export to markets that use American or British plugs.