Search results

  1. Results From The WOW.Com Content Network
  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Phasor diagram showing 240 V delta and center-tapped phase (a–c) creating two 120 V pairs. Consider the low-voltage side of a 120/240 V high leg delta connected transformer, where the b phase is the high leg. The line-to-line voltage magnitudes are all the same: = = =.

  3. File:High leg delta.svg - Wikipedia

    en.wikipedia.org/wiki/File:High_leg_delta.svg

    English: Topographic diagram of the high-leg delta electrical transformer configuration. Phases a, b, and c provide three-phase 240 V power; while phases a and c each provide single-phase 120 V power from the shared neutral n, or split-phase 240 V power between each other.

  4. File:High leg delta transformer.svg - Wikipedia

    en.wikipedia.org/wiki/File:High_leg_delta...

    You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.

  5. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    The number is in units of 30 degrees. For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Except in a high-leg delta system and a corner-grounded delta system, single-phase loads may be connected across any two phases, or a load can be connected from phase to neutral. [28] Distributing single-phase loads among the phases of a three-phase system balances the load and makes most economical use of conductors and transformers.

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...

  8. Top multi-leg options strategies for advanced traders - AOL

    www.aol.com/finance/top-multi-leg-options...

    When to use it: This multi-leg options strategy works well when you expect the stock to fall moderately. The spread reduces your break-even point and allows you to multiply your money faster for a ...

  9. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    If the secondary is a delta winding, the ground may be connected to a center tap on one winding (high leg delta) or one phase may be grounded (corner grounded delta). A special purpose polyphase transformer is the zigzag transformer. There are many possible configurations that may involve more or fewer than six windings and various tap connections.