When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. TIA-569-B - Wikipedia

    en.wikipedia.org/wiki/TIA-569-B

    The Telecommunications Industry Association's TIA-569-B is a Commercial Building Standard for Telecommunications Pathways and Spaces standardizes specific pathway and space design and construction practices in support of telecommunications media and equipment within buildings.

  3. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  4. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    Contact load in amperes for heaters (AC1) and motors (AC3) can be found directly on the contactor. The "Utilization category" are mainly categorized in IEC 60947 in the following volume: Volume 1: General requirements; Volume 2: Circuit-breakers; Volume 3: Circuit-breakers, circuit-breakers, switch-disconnectors and switch-fuse units

  5. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    Contact resistance values are typically small (in the microohm to milliohm range). Contact resistance can cause significant voltage drops and heating in circuits with high current. Because contact resistance adds to the intrinsic resistance of the conductors, it can cause significant measurement errors when exact resistance values are needed.

  6. Electrical contact - Wikipedia

    en.wikipedia.org/wiki/Electrical_contact

    Contact force or pressure increases the size of the a-spot which decreases the constriction resistance and the electrical contact resistance. [11] When the size of contacting asperities becomes larger than the mean free path of electrons, Holm-type contacts become the dominant transport mechanism, resulting in a relatively low contact ...

  7. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  8. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  9. Contact breaker - Wikipedia

    en.wikipedia.org/wiki/Contact_breaker

    Breaker arm with contact points at the left. The pivot is on the right and the cam follower is in the middle of the breaker arm. A contact breaker (or "points") is a type of electrical switch, found in the ignition systems of spark-ignition internal combustion engines. The switch is automatically operated by a cam driven by the engine.