Search results
Results From The WOW.Com Content Network
Because of its reduced global warming potential (GWP), R-454B is intended to be an alternative to refrigerant R-410A in new equipment. [2] [3] [4] R-454B has a GWP of 466, which is 78 percent lower than R-410A's GWP of 2088. [2] R-454B is non-toxic and mildly flammable, with an ASHRAE safety classification of A2L. In the United States, it is ...
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...
The EPA defines refrigerant reclamation as "Reclaim refrigerant means to reprocess refrigerant to at least the purity specified in appendix A to 40 CFR part 82, subpart F (based on AHRI Standard 700–1993, Specifications for Fluorocarbon and Other Refrigerants) and to verify this purity using the analytical methodology prescribed in appendix A ...
A ton of refrigeration (TR or TOR), also called a refrigeration ton (RT), is a unit of power used in some countries (especially in North America) to describe the heat-extraction capacity of refrigeration and air conditioning equipment.
HCFC-123 is used in large tonnage centrifugal chiller applications, and is the most efficient refrigerant currently in use in the marketplace for HVAC applications. HCFC-123 is also used as a testing agent for bypass leakage of carbon adsorbers in gas filtration systems, and as the primary chemical in Halotron I fire-extinguishing agent. [2]
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Trichlorofluoromethane was first widely used as a refrigerant.Because of its high boiling point compared to most refrigerants, it can be used in systems with a low operating pressure, making the mechanical design of such systems less demanding than that of higher-pressure refrigerants R-12 or R-22.