When.com Web Search

  1. Ads

    related to: unbalanced load neutral calculation tool for electrical circuit

Search results

  1. Results From The WOW.Com Content Network
  2. Power engineering software - Wikipedia

    en.wikipedia.org/wiki/Power_engineering_software

    Power engineering software is a software used to create models, analyze or calculate the design of Power stations, Overhead power lines, Transmission towers, Electrical grids, Grounding and Lightning [clarification needed] systems and others. It is a type of application software used for power engineering problems which are transformed into ...

  3. CPC theory - Wikipedia

    en.wikipedia.org/wiki/CPC_Theory

    The existence of a load-generated current that transfers energy from the load back to the supply source was revealed in such circuits. The development of power theory and methods of compensation in single-phase circuits has created a ground for the development of such a theory of three-phase circuits both with sinusoidal, nonsinusoidal, and ...

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    Since we have shown that the neutral current is zero we can see that removing the neutral core will have no effect on the circuit, provided the system is balanced. Such connections are generally used only when the load on the three phases is part of the same piece of equipment (for example a three-phase motor), as otherwise switching loads and ...

  5. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    In electrical engineering, the method of symmetrical components simplifies analysis of unbalanced three-phase power systems under both normal and abnormal conditions. The basic idea is that an asymmetrical set of N phasors can be expressed as a linear combination of N symmetrical sets of phasors by means of a complex linear transformation. [1]

  6. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  7. Unbalanced circuit - Wikipedia

    en.wikipedia.org/wiki/Unbalanced_circuit

    Many transmission lines are intrinsically an unbalanced format such as the widely used coaxial cable. In such cases the circuit can be directly connected to the line. However, connecting an unbalanced circuit to, for instance, a twisted pair line, which is an intrinsically balanced format, makes the line susceptible to common-mode interference.

  8. Balanced circuit - Wikipedia

    en.wikipedia.org/wiki/Balanced_circuit

    A circuit that has the specific purpose of allowing interfacing between balanced and unbalanced circuits is called a balun. A balun could be a transformer with one leg earthed on the unbalanced side as described in the transformer balance section above. Other circuits are possible such as autotransformers or active circuits. [4]

  9. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Short circuit analysis analyzes the power flow after a fault occurs in a power network. The faults may be three-phase short circuit, one-phase grounded, two-phase short circuit, two-phase grounded, one-phase break, two-phase break or complex faults. Results of such an analysis may help determine the following: Magnitude of the fault current