When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Single-unit recording - Wikipedia

    en.wikipedia.org/wiki/Single-unit_recording

    Silicon electrodes are alloy electrodes doped with silicon and an insulating glass cover layer. Silicon technology provides better mechanical stiffness and is a good supporting carrier to allow for multiple recording sites on a single electrode. [31] Tungsten electrodes are very rugged and provide very stable recordings. This allows ...

  3. Electrophysiology - Wikipedia

    en.wikipedia.org/wiki/Electrophysiology

    An electrode introduced into the brain of a living animal will detect electrical activity that is generated by the neurons adjacent to the electrode tip. If the electrode is a microelectrode, with a tip size of about 1 micrometre, the electrode will usually detect the activity of at most one neuron.

  4. Electroencephalography - Wikipedia

    en.wikipedia.org/wiki/Electroencephalography

    An EEG recording setup using the 10-10 system of electrode placement. EEG is the gold standard diagnostic procedure to confirm epilepsy.The sensitivity of a routine EEG to detect interictal epileptiform discharges at epilepsy centers has been reported to be in the range of 29–55%. [8]

  5. Patch clamp - Wikipedia

    en.wikipedia.org/wiki/Patch_clamp

    During a patch clamp recording, a hollow glass tube known as a micropipette or patch pipette filled with an electrolyte solution and a recording electrode connected to an amplifier is brought into contact with the membrane of an isolated cell. Another electrode is placed in a bath surrounding the cell or tissue as a reference ground electrode ...

  6. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...

  7. Event-related potential - Wikipedia

    en.wikipedia.org/wiki/Event-related_potential

    For example, in the checkerboard paradigm described above, healthy participants' first response of the visual cortex is around 50–70 ms. This would seem to indicate that this is the amount of time it takes for the transduced visual stimulus to reach the cortex after light first enters the eye .

  8. Auditory brainstem response - Wikipedia

    en.wikipedia.org/wiki/Auditory_brainstem_response

    Analysis is dependent upon the fact that related bioelectric events coincide with the stimulus repetition rate. The specific analysis method is based on the manufacturer's detection algorithm. It occurs in the spectral domain and is composed of specific frequency components that are harmonics of the stimulus repetition rate.

  9. Electrodermal activity - Wikipedia

    en.wikipedia.org/wiki/Electrodermal_activity

    The electrodes are normally placed about an inch apart, and the resistance recorded varies according to the emotional state of the subject. Galvanic skin potential (GSP) refers to the voltage measured between two electrodes without any externally applied current. It is measured by connecting the electrodes to a voltage amplifier.