When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  3. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.

  4. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.

  5. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    PDs are initiated by defects during manufacture or higher stress dictated by design considerations. Measurements can be collected to detect these PDs and monitor the soundness of insulation. PDs manifest as sharp current pulses at transformer terminals, whose nature depends on the types of insulation, defects, measuring circuits, and detectors ...

  6. Copper loss - Wikipedia

    en.wikipedia.org/wiki/Copper_loss

    For low-frequency applications, the power loss can be minimized by employing conductors with a large cross-sectional area, made from low-resistivity metals.With high-frequency currents, the proximity effect and skin effect cause the current to be unevenly distributed across the conductor, increasing its effective resistance, and making loss calculations more difficult.

  7. Template:Electric transformers - Wikipedia

    en.wikipedia.org/wiki/Template:Electric_transformers

    A navigational box that can be placed at the bottom of articles. Template parameters [Edit template data] Parameter Description Type Status State state The initial visibility of the navbox Suggested values collapsed expanded autocollapse String suggested Template transclusions Transclusion maintenance Check completeness of transclusions The above documentation is transcluded from Template ...

  8. Short-circuit inductance - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_inductance

    Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications.

  9. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60949 Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects; IEC 60950 Information technology equipment – Safety; IEC 60951 Nuclear power plants – Instrumentation important to safety – Radiation monitoring for accident and post-accident conditions; IEC 60952 Aircraft batteries