When.com Web Search

  1. Ads

    related to: toshiba efuse short circuit protection calculation

Search results

  1. Results From The WOW.Com Content Network
  2. eFuse - Wikipedia

    en.wikipedia.org/wiki/EFuse

    In computing, an eFuse (electronic fuse) is a microscopic fuse put into a computer chip. This technology was invented by IBM in 2004 [ 1 ] to allow for the dynamic real-time reprogramming of chips. In the abstract, computer logic is generally "etched" or "hard-wired" onto a chip and cannot be changed after the chip has finished being manufactured.

  3. Polyfuse (PROM) - Wikipedia

    en.wikipedia.org/wiki/Polyfuse_(PROM)

    A polyfuse is a one-time-programmable memory component used in semiconductor circuits for storing unique data like chip identification numbers or memory repair data, but more usually small to medium volume production of read only memory devices or microcontroller chips.

  4. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Calculation of the required breaking capacity involves determining the supply impedance and voltage. Supply impedance is calculated from the impedance of the elements making up the supply system. Customers of an electrical supply utility can request the maximum value of prospective short-circuit current available at their point of supply.

  5. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    Current limiting is the practice of imposing a limit on the current that may be delivered to a load to protect the circuit generating or transmitting the current from harmful effects due to a short-circuit or overload. The term "current limiting" is also used to define a type of overcurrent protective device.

  6. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In a "ground fault" or "earth fault", current flows into the earth. The prospective short-circuit current of a predictable fault can be calculated for most situations. In power systems, protective devices can detect fault conditions and operate circuit breakers and other devices to limit the loss of service due to a failure.

  7. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  8. Conditional short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Conditional_short-circuit...

    Conditional short-circuit current is the value of the alternating current component of a prospective current, which a switch without integral short-circuit protection, but protected by a suitable short circuit protective device (SCPD) in series, can withstand for the operating time of the current under specified test conditions.

  9. Short circuit - Wikipedia

    en.wikipedia.org/wiki/Short_circuit

    A short circuit is an abnormal connection between two nodes of an electric circuit intended to be at different voltages. This results in an electric current limited only by the Thévenin equivalent resistance of the rest of the network which can cause circuit damage, overheating, fire or explosion.