When.com Web Search

  1. Ads

    related to: design calculation of cooling tower area

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    A typical evaporative, forced draft open-loop cooling tower rejecting heat from the condenser water loop of an industrial chiller unit Natural draft wet cooling hyperboloid towers at Didcot Power Station (UK) Forced draft wet cooling towers (height: 34 meters) and natural draft wet cooling tower (height: 122 meters) in Westphalia, Germany Natural draft wet cooling tower in Dresden (Germany)

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  4. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  5. NTU method - Wikipedia

    en.wikipedia.org/wiki/NTU_Method

    The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...

  6. Evaporative cooler - Wikipedia

    en.wikipedia.org/wiki/Evaporative_cooler

    For arid climates with a great wet-bulb depression, cooling towers can provide enough cooling during summer design conditions to be net zero. For example, a 371 m 2 (4,000 ft 2 ) retail store in Tucson, Arizona with a sensible heat gain of 29.3 kJ/h (100,000 Btu/h) can be cooled entirely by two passive cooling towers providing 11890 m 3 /h ...

  7. Hyperboloid structure - Wikipedia

    en.wikipedia.org/wiki/Hyperboloid_structure

    Hence they are more commonly used in purpose-driven structures, such as water towers (to support a large mass), cooling towers, and aesthetic features. [3] A hyperbolic structure is beneficial for cooling towers. At the bottom, the widening of the tower provides a large area for installation of fill to promote thin film evaporative cooling of ...