Search results
Results From The WOW.Com Content Network
Automatic meter reading (AMR) is the technology of automatically collecting consumption, diagnostic, and status data from water meter or energy metering devices (gas, electric) and transferring that data to a central database for billing, troubleshooting, and analyzing. This technology mainly saves utility providers the expense of periodic ...
Unbalanced, symmetrical circuit. Fig. 3. Balanced, asymmetrical circuit. Fig. 4. Balanced, symmetrical circuit. A balanced circuit will normally show a symmetry of its components about a horizontal line midway between the two conductors (example in figure 3). This is different from what is normally meant by a symmetrical circuit, which is a ...
These three components complete a full circuit for a signal to travel through and the impedances of this circuit is what determines whether the interface as a whole is balanced or not: [3] "A balanced circuit is a two-conductor circuit in which both conductors and all circuits connected to them have the same impedance to ground and to all other ...
A typical water meter register showing a meter reading of 8.3 gallons. Notice the black "1" on the odometer has not yet fully turned over, so only the red hand is read. Water meters connected to remote reading devices through three-wire cables. There are several types of registers on water meters.
RS-422 is the common short form title of American National Standards Institute (ANSI) standard ANSI/TIA/EIA-422-B Electrical Characteristics of Balanced Voltage Differential Interface Circuits and its international equivalent ITU-T Recommendation T-REC-V.11, [2] also known as X.27.
Meter data management (MDM) refers to software that performs long-term data storage and management for the vast quantities of data delivered by smart metering systems. This data consists primarily of usage data and events that are imported from the head-end servers managing the data collection in advanced metering infrastructure (AMI) or automatic meter reading (AMR) systems.
Balancing limits the flow in favoured circuits, forcing water through unfavored circuits. As a result, the required design flows are available to all circuits and the system can provide the required indoor air quality. Avoiding overflows means the pump is not doing unnecessary work which saves energy, reduces operating cost and can reduce the ...
In a variable primary chilled-water system, the design flow rate is determined by the water flow velocity in the tube of the coils. At typical conditions, 6–7 feet per second (1.8–2.1 m/s) Maximum 12 ft/s (3.7 m/s) Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1]