A normal nonstress test will show a baseline fetal heart rate between 110 and 160 beats per minute with moderate variability (5- to 25-interbeat variability) and 2 qualifying accelerations in 20 minutes with no decelerations. "Reactive" is defined as the presence of two or more fetal heart rate accelerations within a 20-minute period. Each ...
Vibroacoustic stimulation (VAS), sometimes referred to as fetal vibroacoustic stimulation or fetal acoustic stimulation test (FAST), is the application of a vibratory sound stimulus to the abdomen of a pregnant woman to induce FHR (fetal heart rate) accelerations.
A firm digital pressure on head or a gentle pinch of fetal head with atraumatic clamp is used for stimulation. An acceleration of the fetal heart rate of 15 bpm lasting at least 15 seconds is suggestive of normal fetal outcome.
A Zigzag pattern of fetal heart rate (FHR) is defined as FHR baseline amplitude changes of more than 25 beats per minute (bpm) with a minimum duration of 2 minutes and maximum of 30 minutes. [19] However, according to another study, even a >1 min duration of the zigzag pattern is associated with an increased risk of adverse neonatal outcomes. [21]
The condition is detected most often with electronic fetal heart rate (FHR) monitoring through cardiotocography (CTG), which allows clinicians to measure changes in the fetal cardiac response to declining oxygen. [1] [5] [4] Specifically, heart rate decelerations detected on CTG can represent danger to the fetus and to delivery. [4]
Amnioinfusion is a method in which isotonic fluid is instilled into the uterine cavity.. It was introduced in the 1960s as a means of terminating pregnancy and inducing labor in intrauterine death, but is currently used as a treatment in order to correct fetal heart rate changes caused by umbilical cord compression, indicated by variable decelerations seen on fetal heart rate monitoring.
During uterine contractions, fetal oxygenation is worsened. Late decelerations in fetal heart rate occurring during uterine contractions are associated with increased fetal death rate, growth retardation and neonatal depression. [1] [2] This test assesses fetal heart rate in response to uterine contractions via electronic fetal monitoring.
Histopathology of placenta with increased syncytial knotting of chorionic villi, with two knots pointed out. The following characteristics of placentas have been said to be associated with placental insufficiency, however all of them occur in normal healthy placentas and full term healthy births, so none of them can be used to accurately diagnose placental insufficiency: [citation needed]