When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Leakage inductance - Wikipedia

    en.wikipedia.org/wiki/Leakage_inductance

    Fig. 1 L P σ and L S σ are primary and secondary leakage inductances expressed in terms of inductive coupling coefficient under open-circuited conditions.. The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ.

  3. Severity factor - Wikipedia

    en.wikipedia.org/wiki/Severity_factor

    The FDSF is calculated at transformer terminals and it is mathematically defined as = ()where ω is the angular frequency, ESD noStd (ω) is the maximum energy spectral density of the input no-standard transient voltage applied at transformer terminals and ESD envol (ω) is the energy spectral density envelope for all standards dielectric tests at terminals.

  4. Sweep frequency response analysis - Wikipedia

    en.wikipedia.org/wiki/Sweep_frequency_response...

    A change in winding position, degradation in the insulation, etc. will result in change in capacitance or inductance thereby affecting the measured curves. [ 2 ] Tests are carried out periodically or during major external events like short circuits and results compared against the initial signature to test for any problems.

  5. Coil winding technology - Wikipedia

    en.wikipedia.org/wiki/Coil_winding_technology

    When looking at the insulated winding space graphically and the required number of windings at a given wire diameter, it can be said that considering the space requirements for the winding nozzle (required groove width: about 3*0.548=1.6 mm) only 38 windings can be introduced into the winding space of the stator slot.

  6. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.

  7. Copper loss - Wikipedia

    en.wikipedia.org/wiki/Copper_loss

    Copper loss is the term often given to heat produced by electrical currents in the conductors of transformer windings, or other electrical devices. Copper losses are an undesirable transfer of energy, as are core losses, which result from induced currents in adjacent components.

  8. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    Nine-winding, three-phase transformers typically have three primaries and six identical secondary windings, which can be used in zigzag winding connection as pictured. [1] A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in ...

  9. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    In contrast to the parallel shunt component, the series component in the circuit diagram represents the winding losses due to the resistance of the coil windings of the transformer. Current, voltage and power are measured at the primary winding to ascertain the admittance and power-factor angle.